Industrial Chiller Plant
Industrial Chiller Plant

Industrial Chiller Plant

Price 100000.0 INR/ Piece

MOQ : 1 Piece

Industrial Chiller Plant Specification

  • Motor
  • Premium Efficiency IE3 Motor
  • Air Flow
  • 3500 to 8000 m /h m3/hr
  • Refrigerating Capacity
  • 5 TR to 120 TR
  • Material
  • Other
  • Application
  • Industrial Process Cooling, HVAC, Food Processing
  • Condition
  • New
  • Type
  • Air Cooled/Water Cooled
  • Dimension (L*W*H)
  • 2300 x 1100 x 1750 mm (Variable as per Capacity) Millimeter (mm)
  • Product Type
  • CHILLING PLANT
  • Power Supply
  • Three Phase, 50 Hz, AC Supply
  • Voltage
  • 380-415 V Volt (v)
  • Cooling Type
  • Indirect Glycol / Direct Expansion
  • Nozzle Material
  • Stainless Steel
  • Cooling Coil Material
  • Inner Grooved Copper Tubes with Aluminum Fins
  • Water Flowing Rate
  • 60 LPM (Adjustable)
  • Water Pump Motor
  • 2 HP / 3 HP (as per model)
  • Compressor
  • Hermetically Sealed Scroll Type
  • Warranty
  • 1 Year warranty period
  • Control System
  • Microprocessor based digital temperature controller
  • Condenser
  • Air cooled fin & tube / Water cooled shell & tube
  • Expansion Device
  • Thermostatic Expansion Valve
  • Operating Temperature Range
  • +2C to +25C
  • Color
  • Blue & White (Customizable on request)
  • Safety Features
  • High & Low Pressure Cutout, Phase Failure Protection, Overload Relay
  • Evaporator
  • Shell & Tube / Brazed Plate Type
  • Caster Wheels
  • Heavy Duty Lockable Wheels for Portability
  • Refrigerant Used
  • R-22 / R-407C / R-410A / R-134a
  • Service Support
  • On-site Installation & Training Provided
  • Water Tank Capacity
  • 100 Liters to 500 Liters (Model Dependent)
  • Energy Efficiency
  • High EER / COP design
 

Industrial Chiller Plant Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 3 Pieces Per Week
  • Delivery Time
  • 3 Days
  • Main Export Market(s)
  • Africa, North America, South America, Eastern Europe, Western Europe, Asia, Australia, Central America, Middle East
  • Main Domestic Market
  • All India
 

About Industrial Chiller Plant

The energy efficiency and operational stability are further enhanced by optimized compressor selection and precision-engineered components. Continuous operation with minimum vibration and noise is supported, fitting for heavy industrial use. Easy-access panels and a well-arranged layout make inspection and servicing easier. Every unit is tested acutely for the accuracy of performance and quality standards. Variations in the design allow it to be integrated into the current production lines without hassle. From reliable cooling to long-life services, this chiller plant maintains constant thermal control and advances industrials for cost-effective and uninterruptible operation.

Technical specification of Industrial Chiller Plant

Minimum Order Quantity

1 Unit

Automatic Grade

Semi-Automatic

Capacity ( in Tons)

10 to 250

Phase

Three Phase

Motor

1 to 200 HP

Power

250 KW

Product Details:

Capacity ( in Tons)

as per requirement



Microprocessor Digital Temperature Control

Featuring a sophisticated microprocessor-based digital temperature controller, our chiller plant maintains precise operating temperatures between +2C to +25C. This ensures reliable performance for sensitive industrial applications and maximizes process consistency. The intuitive controller interface allows straightforward adjustments, monitoring, and error notifications, supporting both novice and experienced operators.

Flexible Refrigerant and Cooling Options

Our chillers accommodate multiple refrigerants, including R-22, R-407C, R-410A, and R-134a, to meet varying environmental and efficiency standards. Customers can opt for air cooled fin & tube or water cooled shell & tube condensers, choosing the ideal cooling solution for their unique facility requirements. Customizable features ensure compatibility across diverse industrial sectors.

Comprehensive Safety and Reliability

Safety features include high and low pressure cutouts, phase failure protection, and overload relays that safeguard both equipment and operators. With robust construction, powder-coated steel chassis, and stainless steel nozzles, the chiller plant is built for long-term reliability, reducing downtime and minimizing maintenance demands.

FAQ's of Industrial Chiller plant:


Q: How do I select the appropriate chiller model for my industrial application?

A: Selection depends on your cooling capacity needs (5 TR to 120 TR), desired water tank size (100-500 liters), process type (HVAC, food processing, etc.), and available power supply (three phase, 380-415 V, 50 Hz). Our team provides consultation to help determine the best match based on your operational requirements.

Q: What safety mechanisms are integrated into the chiller plant?

A: The system includes high and low pressure cutouts, phase failure protection, and overload relays to prevent operational hazards. These features protect both the equipment and users from potential electrical issues, pressure irregularities, and mechanical overloads.

Q: Where can I access installation and training for the chiller system?

A: We offer on-site installation and training services across India, ensuring your staff are fully equipped to operate and maintain the system efficiently. Our support extends to exporters, manufacturers, and suppliers seeking expert guidance during setup.

Q: What are the benefits of using a microprocessor-based digital temperature controller?

A: The controller delivers accurate, stable temperature management and fast response times. It enables easy monitoring, adjustment, and troubleshooting, enhancing process control and reducing the risk of temperature-related damage or inefficiency.

Q: When should routine maintenance be performed on the chiller plant?

A: Regular maintenance should be scheduled according to usage frequency and operating conditions. We recommend monthly inspections of safety features and quarterly servicing of components like expansion valves, compressors, and condenser coils to ensure optimal performance.

Q: What types of cooling methods are supported by this chiller plant?

A: Our units support indirect glycol or direct expansion cooling types, allowing flexibility for various process demands. The cooling coil construction uses inner grooved copper tubes with aluminum fins for superior heat exchange efficiency.

Q: How does the chiller plant contribute to energy efficiency and noise control?

A: Equipped with premium efficiency IE3 motors and high EER/COP design, our chillers minimize energy consumption while maintaining cooling efficacy. Additionally, acoustic insulation and low noise operation enhance workplace comfort and reduce environmental impact.

Technical Details 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Chilling Plant Category

Water Cooling Chillers

Water Cooling Chillers

Price 250000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Condition : New

Nozzle Material : PVC

Application : Industrial

Power Supply : Electric

Water Cooled Chilling Plant

Water Cooled Chilling Plant

Price 50000 INR

Condition : New

Nozzle Material : Brass

Application : Cooling in industries manufacturing units

Power Supply : 415V/3Phase/50Hz

Roof Top Chiller Plant

Roof Top Chiller Plant

Price 400000.00 INR

Minimum Order Quantity : 1

Condition : New

Nozzle Material : Stainless Steel

Application : Commercial, Industrial, Residential HVAC systems

Power Supply : 3 Phase, 50 Hz

Water Chilling Machine Plant

Water Chilling Machine Plant

Price 50000 INR

Condition : New

Nozzle Material : Stainless Steel

Application : Industrial/Commercial Water Chilling

Power Supply : 3 Phase, 50 Hz



Back to top