Water Cooled Water Chiller Plant Specification

  • Motor
  • High Efficiency Three-Phase Motor
  • Refrigerating Capacity
  • 5 TR - 300 TR (Tons of Refrigeration)
  • Material
  • Other
  • Application
  • Industrial Process Cooling, Centralized AC, Pharma, Chemical
  • Condition
  • New
  • Type
  • Water Cooled
  • Power Supply
  • 3 phase
  • Cooling Type
  • Water Cooled
  • Nozzle Material
  • Stainless Steel (SS304/SS316)
  • Cooling Coil Material
  • Copper with Hydrophilic Fins
  • Water Flowing Rate
  • 50 - 500 LPM (Variable by Model)
  • Water Pump Motor
  • Energy Efficient Motor with IP55 Protection
  • Compressor
  • Semi Hermetic / Scroll Type
  • Evaporator Type
  • Shell and Tube / Plate Heat Exchanger
  • Insulation
  • CFC Free PUF / Nitrile Rubber Insulation
  • Condenser Type
  • Shell & Tube Water Cooled Condenser
  • Refrigerant Type
  • R134A / R407C / R22 as per Requirement
  • Pipe Connections
  • Flanged/Grooved End
  • Capacity Control
  • Step / Continuous Capacity Control
  • Safety Features
  • High/Low Pressure Control, Overload Protection, Water Flow Switch
  • Expansion Valve
  • Thermal / Electronic Expansion Valve
  • Chiller Control Panel
  • PLC / Microprocessor Based Automatic Control
  • Display
  • Digital Temperature & Parameter Display
 

Water Cooled Water Chiller Plant Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 1 Piece Per Day
  • Delivery Time
  • 1 Week
  • Main Domestic Market
  • Gujarat
 

About Water Cooled Water Chiller Plant

Water Cooled Water Chiller Plant 

Backed by immense support of our adroit professionals, we are able to manufacture, supply and export Water Cooled Water Chiller Plant. This chilling plant is designed in our manufacturing units in strict conformance with international standards. Owing to its high performance, reliable efficiency, easy installation, high speed operation and low power consumption, it is highly appreciated in the market. Water Cooled Water Chiller Plant is extensively being used in institutes, commercial sectors and industrial units.

We Are Leading Manufacturer & Supplier Of Water Cooled Water Chiller Plant From Ahemdabad

Technical Specifications

Automatic Grade

Automatic

Phase

Three Phase

Motor

1 to 200 HP

Temperature

+30 degree Celsius to -10 degree Celsius

Application

Power Plant




Advanced Control System for Optimal Operation

Equipped with a PLC or microprocessor-based control panel, this chiller plant provides automatic regulation of temperature and system parameters. The digital display allows users to monitor real-time performance and easily manage settings, ensuring operational consistency and reducing downtime. Step or continuous capacity control further optimizes energy use based on cooling requirements.


Efficient Cooling Technology and Safety Features

Our chiller plant utilizes both shell and tube or plate heat exchangers to maximize heat transfer efficiency. Safety is enhanced by integrated high/low pressure controls, overload protection, and water flow switches. The unit's CFC-free insulation and noise levels below 70 dB(A) prioritize environmental responsibility and quiet operation, ideal for industrial settings.


Customizable Capacity for Diverse Applications

Designed for versatility, the Water Cooled Chiller Plant can be tailored in size and configuration to fit specific requirements. Serving centralized air conditioning, industrial process cooling, and pharmaceutical or chemical operations, its wide range of refrigeration capacities and flexible flow rates support multiple industries with robust and reliable cooling performance.

FAQ's of Water Cooled Water Chiller Plant:


Q: How do I select the suitable refrigerant for my Water Cooled Chiller Plant?

A: The choice of refrigerant-R134A, R407C, or R22-depends on your process requirements, environmental regulations, and system compatibility. R134A is preferred for higher efficiency and environmental friendliness, while R407C suits moderate applications. It's recommended to consult your supplier to match the refrigerant to your cooling and regulatory needs.

Q: What type of control panel is included with the chiller plant, and how does it benefit system operation?

A: Our chiller features a PLC or microprocessor-based automatic control panel. This advanced system ensures precise temperature management, displays real-time parameters digitally, and facilitates step or continuous capacity adjustment, leading to consistent performance and enhanced energy savings.

Q: When is it necessary to use a thermal or electronic expansion valve in this chiller plant?

A: Thermal expansion valves are ideal for stable load conditions, while electronic expansion valves are recommended for processes with fluctuating loads or advanced control needs. Depending on your application complexity and load variability, you can select the most appropriate valve type for optimal efficiency.

Q: Where can the Water Cooled Chiller Plant be installed?

A: The chiller plant is suitable for installation in industrial facilities, centralized air conditioning systems, pharmaceutical manufacturing, and chemical processing units. Its customizable dimensions ensure compatibility with varied site requirements, while the mild steel anti-corrosive body withstands demanding environments.

Q: What is the process for maintaining safety features like overload protection and water flow switches?

A: Regular system inspections and preventative maintenance are essential. Ensure the water flow switch is functional, check and reset overload protection as needed, and monitor high/low pressure controls via the digital display to promptly address any irregularities, maintaining continuous safe operation.

Q: How does the variable water flow rate enhance chiller performance?

A: The plant is equipped with models offering water flow rates from 50 to 500 LPM. This flexibility enables precise cooling adjustments for different processes, maximizing energy efficiency and meeting diverse application requirements without compromising system effectiveness.

Q: What benefits does CFC-free PUF or nitrile rubber insulation provide in this chiller plant?

A: CFC-free PUF and nitrile rubber insulation minimize thermal losses, improve cooling efficiency, and support environmental responsibility by avoiding harmful chlorofluorocarbons. Additionally, these materials help maintain consistent temperatures and reduce energy consumption.

Technical Details 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Chillers Manufacturer Category

Industrial Water Chiller

Industrial Water Chiller

Price 100000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Refrigerating Capacity : As Applicable

Condition : New

Material : Copper

Nozzle Material : SS / MS / Copper

Screw Chiller

Screw Chiller

Price 100000.00 INR

Minimum Order Quantity : 1 Piece

Refrigerating Capacity : 50 TR 400 TR

Condition : New

Material : Other

Nozzle Material : Brass/Stainless Steel

Medical Chillers

Medical Chillers

Price 100000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Refrigerating Capacity : 5 TR

Condition : New

Material : Other

Nozzle Material : Stainless Steel

Air Chiller Systems

Air Chiller Systems

Price 100000.00 INR / Piece

Minimum Order Quantity : 1 , , Piece

Refrigerating Capacity : As Applicable

Condition : New

Material : Copper

Nozzle Material : SS / MS / Copper